International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 89
Page iii
International Code Council. PREFACE Introduction Internationally , code officials recognize the need for a modern , up - to - date residential construction code addressing the design and construction of one- and two - family dwellings ...
International Code Council. PREFACE Introduction Internationally , code officials recognize the need for a modern , up - to - date residential construction code addressing the design and construction of one- and two - family dwellings ...
Page 38
... building shall be designed as a partially enclosed building in accordance with the International Building Code . Glazed opening protection for windborne debris shall meet the require- ments of the Large Missile Test of ASTM E 1996 and ...
... building shall be designed as a partially enclosed building in accordance with the International Building Code . Glazed opening protection for windborne debris shall meet the require- ments of the Large Missile Test of ASTM E 1996 and ...
Page 39
International Code Council. R301.2.2 Seismic provisions . The seismic provisions of this code ... code . The weight limitations of Section R301.2.2.4 shall apply to buildings in all ... RESIDENTIAL CODE® 39 BUILDING PLANNING R301.2.2 - R301.2.2 ...
International Code Council. R301.2.2 Seismic provisions . The seismic provisions of this code ... code . The weight limitations of Section R301.2.2.4 shall apply to buildings in all ... RESIDENTIAL CODE® 39 BUILDING PLANNING R301.2.2 - R301.2.2 ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel