International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 56
Page 39
... Seismic Design Category C are exempt from the seismic requirements of this code . The weight limitations of Section R301.2.2.4 shall apply to buildings in all Seismic Design Categories regulated by this code . Buildings in Seismic Design ...
... Seismic Design Category C are exempt from the seismic requirements of this code . The weight limitations of Section R301.2.2.4 shall apply to buildings in all Seismic Design Categories regulated by this code . Buildings in Seismic Design ...
Page 40
... Seismic Design Category C. Masonry construction in Seismic Design Category C shall comply with the requirements of Section R606.11.2 . R301.2.2.6 Height limitations in Seismic Design Cate- gories D1 and D2 . Wood frame buildings shall ...
... Seismic Design Category C. Masonry construction in Seismic Design Category C shall comply with the requirements of Section R606.11.2 . R301.2.2.6 Height limitations in Seismic Design Cate- gories D1 and D2 . Wood frame buildings shall ...
Page 58
... Seismic Design Catego- ries D1 and D2 . The braced wall panels at exterior walls of all buildings located in Seismic Design Categories D1 and D2 shall be supported by continuous footings . All required interior braced wall panels in ...
... Seismic Design Catego- ries D1 and D2 . The braced wall panels at exterior walls of all buildings located in Seismic Design Categories D1 and D2 shall be supported by continuous footings . All required interior braced wall panels in ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel