International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 81
Page 290
... appliance location in accordance with Chapter 38 . M1305.1.4 Appliances under floors . Underfloor spaces containing appliances requiring access shall be provided with an unobstructed passageway large enough to remove the largest appliance ...
... appliance location in accordance with Chapter 38 . M1305.1.4 Appliances under floors . Underfloor spaces containing appliances requiring access shall be provided with an unobstructed passageway large enough to remove the largest appliance ...
Page 333
... APPLIANCE , VENTED . A vented appliance wherein the primary function lies in the aesthetic effect of the flames . DECORATIVE GAS APPLIANCES FOR INSTALLA- TION IN VENTED FIREPLACES . A vented appliance designed for installation within ...
... APPLIANCE , VENTED . A vented appliance wherein the primary function lies in the aesthetic effect of the flames . DECORATIVE GAS APPLIANCES FOR INSTALLA- TION IN VENTED FIREPLACES . A vented appliance designed for installation within ...
Page 527
... appliance or of the installation . ( b ) If it is determined there is a condition that could result in unsafe operation , the appliance should be shut off and the owner advised of the unsafe condition . The following steps should be ...
... appliance or of the installation . ( b ) If it is determined there is a condition that could result in unsafe operation , the appliance should be shut off and the owner advised of the unsafe condition . The following steps should be ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel