International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 22
Page 116
... Braced wall lines . Braced wall lines shall consist of braced wall panel construction methods in accordance with Section R602.10.3 . The amount and location of bracing shall be in accordance with Table R602.10.1 and the amount of bracing ...
... Braced wall lines . Braced wall lines shall consist of braced wall panel construction methods in accordance with Section R602.10.3 . The amount and location of bracing shall be in accordance with Table R602.10.1 and the amount of bracing ...
Page 118
International Code Council. TABLE R602.10.3 WALL BRACING SEISMIC DESIGN CATEGORY OR WIND SPEED Category A and B ( S ... line . Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method ...
International Code Council. TABLE R602.10.3 WALL BRACING SEISMIC DESIGN CATEGORY OR WIND SPEED Category A and B ( S ... line . Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method ...
Page 120
... braced wall lines shall be supported on continuous founda- tions at ... line . R602.10.10 Design of structural elements . Where a build- ing , or ... braced wall lines . Spacing between braced wall lines in each story shall not exceed 25 ...
... braced wall lines shall be supported on continuous founda- tions at ... line . R602.10.10 Design of structural elements . Where a build- ing , or ... braced wall lines . Spacing between braced wall lines in each story shall not exceed 25 ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel