International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 20
Page 41
... braced wall panels that are out of plane with braced wall panels below provided that : 1. Floor joists are nominal 2 inches by 10 inches ( 51 mm by 254 mm ) or larger and spaced not more than 16 inches ( 406 mm ) on center ; 2. The ...
... braced wall panels that are out of plane with braced wall panels below provided that : 1. Floor joists are nominal 2 inches by 10 inches ( 51 mm by 254 mm ) or larger and spaced not more than 16 inches ( 406 mm ) on center ; 2. The ...
Page 117
... wall sheathing panels installed in accor- dance with Table R602.3 ( 4 ) . 7. Portland cement plaster on studs spaced ... braced wall panels constructed in accordance with Section R602.10.6 shall be permitted to replace any of the above ...
... wall sheathing panels installed in accor- dance with Table R602.3 ( 4 ) . 7. Portland cement plaster on studs spaced ... braced wall panels constructed in accordance with Section R602.10.6 shall be permitted to replace any of the above ...
Page 120
... braced wall panels shall be supported on continuous foundations . Exception : Two - story buildings shall be permitted to have interior braced wall lines supported on continuous foundations at intervals not exceeding 50 feet ( 15 240 mm ) ...
... braced wall panels shall be supported on continuous foundations . Exception : Two - story buildings shall be permitted to have interior braced wall lines supported on continuous foundations at intervals not exceeding 50 feet ( 15 240 mm ) ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel