International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 34
Page 453
... cable MC Nonmetallic sheathed cable NM Rigid nonmetallic conduit RNC Rigid metallic conduit RMC SE SR UF USE Service entrance cable Surface raceways Underground feeder cable Underground service cable E3701.3 Circuit conductors . All ...
... cable MC Nonmetallic sheathed cable NM Rigid nonmetallic conduit RNC Rigid metallic conduit RMC SE SR UF USE Service entrance cable Surface raceways Underground feeder cable Underground service cable E3701.3 Circuit conductors . All ...
Page 462
... cable . 2. Short sections of raceway used to provide cable assemblies with support or protection against physical damage . E3804.2 Mechanical continuity - raceways and cables . Metal or nonmetallic raceways , cable armors and cable ...
... cable . 2. Short sections of raceway used to provide cable assemblies with support or protection against physical damage . E3804.2 Mechanical continuity - raceways and cables . Metal or nonmetallic raceways , cable armors and cable ...
Page 473
... cable is used , the cable assembly , including the sheath , shall extend into the box not less than 1/4 inch ( 6.4 mm ) through a nonmetallic - sheathed cable knockout opening . E3805.3.2 Securing to box . All permitted wiring methods ...
... cable is used , the cable assembly , including the sheath , shall extend into the box not less than 1/4 inch ( 6.4 mm ) through a nonmetallic - sheathed cable knockout opening . E3805.3.2 Securing to box . All permitted wiring methods ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel