Page 76
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and damp- proofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and damp- proofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
Page 405
... drainage piping ; below - grade drains within the building ( building drain ) ; below- and above- grade venting systems ; and piping to the public sewer or private septic system . P3001.2 Protection from freezing . No portion of the ...
... drainage piping ; below - grade drains within the building ( building drain ) ; below- and above- grade venting systems ; and piping to the public sewer or private septic system . P3001.2 Protection from freezing . No portion of the ...
Page 410
... drainage lines . P3005.2.3 Underground drainage cleanouts . When installed in underground drains , cleanouts shall be extended vertically to or above finished grade either inside or outside the building . P3005.2.4 Change of direction ...
... drainage lines . P3005.2.3 Underground drainage cleanouts . When installed in underground drains , cleanouts shall be extended vertically to or above finished grade either inside or outside the building . P3005.2.4 Change of direction ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel