International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 55
Page 99
... fastened to the bottom flange at each joist with at least one No. 8 screw and shall be fastened to blocking with at least two No. 8 screws . Blocking or bridging ( X - bracing ) shall be installed between joists in - line with straps at ...
... fastened to the bottom flange at each joist with at least one No. 8 screw and shall be fastened to blocking with at least two No. 8 screws . Blocking or bridging ( X - bracing ) shall be installed between joists in - line with straps at ...
Page 161
... fastened to each flange with minimum No. 8 screws as required by Table R603.8.3.2.3 ( 2 ) . R603.8.3.2.4 Ridge strap connection . Roof rafters shall be provided with a connection at the ridge line to transfer tension loads . The ridge ...
... fastened to each flange with minimum No. 8 screws as required by Table R603.8.3.2.3 ( 2 ) . R603.8.3.2.4 Ridge strap connection . Roof rafters shall be provided with a connection at the ridge line to transfer tension loads . The ridge ...
Page 253
... fastened sufficiently in place . 2. Starting at the eave , 36 - inch - wide ( 914 mm ) strips of underlayment felt shall be applied , overlapping successive sheets 19 inches ( 483 mm ) , and fastened sufficiently in place . R905.3.3.2 ...
... fastened sufficiently in place . 2. Starting at the eave , 36 - inch - wide ( 914 mm ) strips of underlayment felt shall be applied , overlapping successive sheets 19 inches ( 483 mm ) , and fastened sufficiently in place . R905.3.3.2 ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/mē less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel