International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 97
Page 88
... Floor underlayment . Particleboard floor underlayment shall conform to Type PBU and shall not be less than 1/4 inch ( 6.4 mm ) in thickness . R503.3.3 Installation . Particleboard underlayment shall be installed in accordance with the ...
... Floor underlayment . Particleboard floor underlayment shall conform to Type PBU and shall not be less than 1/4 inch ( 6.4 mm ) in thickness . R503.3.3 Installation . Particleboard underlayment shall be installed in accordance with the ...
Page 296
... floor area . 6. The floor furnace shall not be installed in concrete floor construction built on grade . 7. The floor furnace shall not be installed where a door can swing within 12 inches ( 305 mm ) of the grill opening . M1408.4 ...
... floor area . 6. The floor furnace shall not be installed in concrete floor construction built on grade . 7. The floor furnace shall not be installed where a door can swing within 12 inches ( 305 mm ) of the grill opening . M1408.4 ...
Page 519
... FLOOR APPLIANCE IF CONNECTOR REQUIREMENT FOR RISE OF TOTAL HEIGHT CANNOT BE MET USE VENT CONNECTOR TABLE RISE TOP FLOOR APPLIANCE USE VENT CONNECTOR TABLE THIRD FLOOR APPLIANCE USE VENT CONNECTOR TABLE SECOND FLOOR APPLIANCE USE VENT ...
... FLOOR APPLIANCE IF CONNECTOR REQUIREMENT FOR RISE OF TOTAL HEIGHT CANNOT BE MET USE VENT CONNECTOR TABLE RISE TOP FLOOR APPLIANCE USE VENT CONNECTOR TABLE THIRD FLOOR APPLIANCE USE VENT CONNECTOR TABLE SECOND FLOOR APPLIANCE USE VENT ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel