Page 11
... heating and / or cooling systems or appliances capa- ble of maintaining , through design or heat loss / gain , 68 ° F ( 20 ° C ) during the heating season and / or 80 ° F ( 27 ° C ) during the cooling season , or has a fixed opening ...
... heating and / or cooling systems or appliances capa- ble of maintaining , through design or heat loss / gain , 68 ° F ( 20 ° C ) during the heating season and / or 80 ° F ( 27 ° C ) during the cooling season , or has a fixed opening ...
Page 329
... heating or cooling , hot water heating , and swimming pool heating . M2301.2 Installation . Installation of solar energy systems shall comply with Sections M2301.2.1 through M2301.2.9 . M2301.2.1 Access . Solar energy collectors ...
... heating or cooling , hot water heating , and swimming pool heating . M2301.2 Installation . Installation of solar energy systems shall comply with Sections M2301.2.1 through M2301.2.9 . M2301.2.1 Access . Solar energy collectors ...
Page 484
... Heating equipment containing motors rated over 0.125 horsepower with supplementary overcurrent protection . ALLOWED ... heating equipment or , in any location , if capable of being locked in the open position . Disconnect permitted to ...
... Heating equipment containing motors rated over 0.125 horsepower with supplementary overcurrent protection . ALLOWED ... heating equipment or , in any location , if capable of being locked in the open position . Disconnect permitted to ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel