... INSULATING CONCRETE FORM ( ICF ) . A concrete forming system using stay - in - place forms of rigid foam plastic insulation , a hybrid of cement and foam insulation , a hybrid of cement and wood chips , or other insulating material for ...
... INSULATING CONCRETE FORM ( ICF ) . A concrete forming system using stay - in - place forms of rigid foam plastic insulation , a hybrid of cement and foam insulation , a hybrid of cement and wood chips , or other insulating material for ...
Page 75
... concrete slab is provided , the unbalanced backfill height shall be measured ... insulating concrete form foundation walls for buildings not greater than 60 ... insulating concrete form wall systems . Flat ICF wall systems shall comply ...
... concrete slab is provided , the unbalanced backfill height shall be measured ... insulating concrete form foundation walls for buildings not greater than 60 ... insulating concrete form wall systems . Flat ICF wall systems shall comply ...
Page 179
... INSULATING CONCRETE FORM WALL CONSTRUCTION R611.1 General . Insulating Concrete Form walls shall be de- signed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318 . When ACI ...
... INSULATING CONCRETE FORM WALL CONSTRUCTION R611.1 General . Insulating Concrete Form walls shall be de- signed and constructed in accordance with the provisions of this section or in accordance with the provisions of ACI 318 . When ACI ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel