... joint thickness tolerance . Mortar joint thickness shall be within the following tolerances from the specified dimensions : 1. Bed joint : +1/8 inch ( 3.2 mm ) . 2. Head joint : 1/4 inch ( 6.4 mm ) , + 3/8 inch ( 9.5 mm ) . 3. Collar joints ...
... joint thickness tolerance . Mortar joint thickness shall be within the following tolerances from the specified dimensions : 1. Bed joint : +1/8 inch ( 3.2 mm ) . 2. Head joint : 1/4 inch ( 6.4 mm ) , + 3/8 inch ( 9.5 mm ) . 3. Collar joints ...
Page 403
International Code Council. P2904.8 Plastic pipe joints . Joints in plastic piping shall be made with approved fittings by solvent cementing , heat fusion , corrosion - resistant metal clamps with insert fittings or com- pression ...
International Code Council. P2904.8 Plastic pipe joints . Joints in plastic piping shall be made with approved fittings by solvent cementing , heat fusion , corrosion - resistant metal clamps with insert fittings or com- pression ...
Page 408
... joints . Threaded joints shall con- form to American National Taper Pipe Thread . Pipe ends . shall be reamed or filed to size and all chips removed . Pipe- joint compound or tape shall be applied on the male threads only . P3003.3.4 ...
... joints . Threaded joints shall con- form to American National Taper Pipe Thread . Pipe ends . shall be reamed or filed to size and all chips removed . Pipe- joint compound or tape shall be applied on the male threads only . P3003.3.4 ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel