International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 39
Page 104
... nail NUMBER AND TYPE OF FASTENERA , b , c , d 3-8d 1 " x 6 " subfloor or less to each joist , face nail 2 " subfloor to joist or girder , blind and face nail Sole plate to joist or blocking , face nail Top or sole plate to stud , end nail ...
... nail NUMBER AND TYPE OF FASTENERA , b , c , d 3-8d 1 " x 6 " subfloor or less to each joist , face nail 2 " subfloor to joist or girder , blind and face nail Sole plate to joist or blocking , face nail Top or sole plate to stud , end nail ...
Page 105
... nail 6d SPACING OF FASTENERS Edges ( inches ) Intermediate supportsc , e ( inches ) 3 6 common nail staple 16 ga . , 1/2 long 3 6 3 6 4 8 11/2 galvanized roofing nail 8d common nail staple 16 ga . , 11/2 long 25/32 structural cellulosic ...
... nail 6d SPACING OF FASTENERS Edges ( inches ) Intermediate supportsc , e ( inches ) 3 6 common nail staple 16 ga . , 1/2 long 3 6 3 6 4 8 11/2 galvanized roofing nail 8d common nail staple 16 ga . , 11/2 long 25/32 structural cellulosic ...
Page 205
... nail 0.120 nail 0.019f Lap No Without 11/2 " long 2 " long Horizontal insulation 0.120 nail 0.120 nail 0.024 Lap No aluminume 11/2 " long 2 " long With 0.120 nail 0.120 nail Gypsum sheathing into stud 0.120 nail 2 " long 0.120 nail 2 " long ...
... nail 0.120 nail 0.019f Lap No Without 11/2 " long 2 " long Horizontal insulation 0.120 nail 0.120 nail 0.024 Lap No aluminume 11/2 " long 2 " long With 0.120 nail 0.120 nail Gypsum sheathing into stud 0.120 nail 2 " long 0.120 nail 2 " long ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel