International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 85
Page 40
... permitted in Seismic Design Category D2 provided the wall bracing amounts in Chapter 6 are increased in accordance with Table R301.2.2.4 . TABLE R301.2.2.4 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa ROOF / CEILING DEAD ...
... permitted in Seismic Design Category D2 provided the wall bracing amounts in Chapter 6 are increased in accordance with Table R301.2.2.4 . TABLE R301.2.2.4 WALL BRACING ADJUSTMENT FACTORS BY ROOF COVERING DEAD LOADa ROOF / CEILING DEAD ...
Page 373
... permitted to be in accordance with the appliance manufacturer's instructions and the terms of the listing . G2427.3.16 ( 504.3.19 ) Connector maximum size . Vent connectors shall not be increased in size more than two sizes greater than ...
... permitted to be in accordance with the appliance manufacturer's instructions and the terms of the listing . G2427.3.16 ( 504.3.19 ) Connector maximum size . Vent connectors shall not be increased in size more than two sizes greater than ...
Page 415
... permitted . Any combination of fixtures within two bathroom groups located on the same floor level are permitted to be vented by a wet vent . The wet vent shall be con- sidered the vent for the fixtures and shall extend from the con ...
... permitted . Any combination of fixtures within two bathroom groups located on the same floor level are permitted to be vented by a wet vent . The wet vent shall be con- sidered the vent for the fixtures and shall extend from the con ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel