International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 75
Page 188
... pound per square inch = 6.895 kPa , 1 pound per square foot = 0.0479 kN / m2 . NOTE : This table is based on concrete with a minimum specified compressive strength of 2,500 psi , reinforcing steel with a minimum yield strength of 40,000 ...
... pound per square inch = 6.895 kPa , 1 pound per square foot = 0.0479 kN / m2 . NOTE : This table is based on concrete with a minimum specified compressive strength of 2,500 psi , reinforcing steel with a minimum yield strength of 40,000 ...
Page 244
... pound per square foot = 0.0479 kN / m2 . a . Screws shall be No. 10 minimum . TABLE R804.3.3.1.1 ( 1 ) RIDGE TENSION STRAP CONNECTION REQUIREMENTS PER FOOT OF RIDGE SPANC BASIC WIND SPEED ( mph ) 110 120 130 110 BASIC WIND SPEED ( mph ) ...
... pound per square foot = 0.0479 kN / m2 . a . Screws shall be No. 10 minimum . TABLE R804.3.3.1.1 ( 1 ) RIDGE TENSION STRAP CONNECTION REQUIREMENTS PER FOOT OF RIDGE SPANC BASIC WIND SPEED ( mph ) 110 120 130 110 BASIC WIND SPEED ( mph ) ...
Page 258
... lb. per double base box , field painted where applicable in accordance with manufacturer's installation instructions . For Sl : 1 inch = 25.4 mm , 1 square foot = 0.0929 m2 , 1 pound = 0.454 kg , 1 ounce per square foot = 305 g / m2 , 1 ...
... lb. per double base box , field painted where applicable in accordance with manufacturer's installation instructions . For Sl : 1 inch = 25.4 mm , 1 square foot = 0.0929 m2 , 1 pound = 0.454 kg , 1 ounce per square foot = 305 g / m2 , 1 ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel