International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 29
Page 456
... raceway permitted for direct burial . The raceways shall be covered by a minimum of 2 inches of concrete extending down to the rock . A seal incorporating the physical protection characteristics of a bushing. 24 3 Nonmetallic raceways ...
... raceway permitted for direct burial . The raceways shall be covered by a minimum of 2 inches of concrete extending down to the rock . A seal incorporating the physical protection characteristics of a bushing. 24 3 Nonmetallic raceways ...
Page 462
... raceway used to provide cable assemblies with support or protection against physical damage . E3804.2 Mechanical continuity - raceways and cables . Metal or nonmetallic raceways , cable armors and cable sheaths shall be continuous ...
... raceway used to provide cable assemblies with support or protection against physical damage . E3804.2 Mechanical continuity - raceways and cables . Metal or nonmetallic raceways , cable armors and cable sheaths shall be continuous ...
Page 475
... raceway or cable is installed with metal boxes , or conduit bodies , the raceway or cable shall be secured to such boxes and conduit bodies . E3806.4 Unused openings . Unused cable or raceway open- ings in boxes and conduit bodies shall ...
... raceway or cable is installed with metal boxes , or conduit bodies , the raceway or cable shall be secured to such boxes and conduit bodies . E3806.4 Unused openings . Unused cable or raceway open- ings in boxes and conduit bodies shall ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel