... Thickness of masonry . The nominal thickness of masonry walls shall conform to the requirements of Sections R606.2.1 through R606.2.4 . R606.2.1 Minimum thickness . The minimum thickness of masonry bearing walls more than one story high ...
... Thickness of masonry . The nominal thickness of masonry walls shall conform to the requirements of Sections R606.2.1 through R606.2.4 . R606.2.1 Minimum thickness . The minimum thickness of masonry bearing walls more than one story high ...
Page 166
... thickness or one - half the wythe thickness for hollow walls ; the maximum projection of one unit shall not exceed one - half the height of the unit or one - third the thickness at right angles to the wall . The top course of corbels ...
... thickness or one - half the wythe thickness for hollow walls ; the maximum projection of one unit shall not exceed one - half the height of the unit or one - third the thickness at right angles to the wall . The top course of corbels ...
Page 285
... THICKNESS inchesb PIPING SYSTEM TYPES Heating systems Low pressure / temperature 201-250 Low temperature 120-200 ... thickness . For materials with an R - value greater than R - 4.6 , the insulation thickness specified in this table may ...
... THICKNESS inchesb PIPING SYSTEM TYPES Heating systems Low pressure / temperature 201-250 Low temperature 120-200 ... thickness . For materials with an R - value greater than R - 4.6 , the insulation thickness specified in this table may ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel