Proceedings of the International School of Physics "Enrico Fermi.", Volume 76N. Zanichelli, 1981 - Nuclear physics |
From inside the book
Results 1-3 of 60
Page 204
... important and can make a display more easily interpreted by the physician . APEX Fig . 9 . - LEFT Color - coded three - dimensional scan of deposition of 133 Xe in the lung . 5.- Derivation of functional parameters . What is becoming a ...
... important and can make a display more easily interpreted by the physician . APEX Fig . 9 . - LEFT Color - coded three - dimensional scan of deposition of 133 Xe in the lung . 5.- Derivation of functional parameters . What is becoming a ...
Page 210
... important to increase lesion detection . The importance of display factors in respect to this evaluation is better recognized now and improvements in lesion detection with several types of filtering have recently been report- ed [ 17 ...
... important to increase lesion detection . The importance of display factors in respect to this evaluation is better recognized now and improvements in lesion detection with several types of filtering have recently been report- ed [ 17 ...
Page 233
... important tool for the diagnosis of many cardiac diseases . The following direct methods are available to achieve these measurements : 1 ) cineangiocardiography , 2 ) radioisotope angiocardiography , 3 ) ultrasound ecocardiography ...
... important tool for the diagnosis of many cardiac diseases . The following direct methods are available to achieve these measurements : 1 ) cineangiocardiography , 2 ) radioisotope angiocardiography , 3 ) ultrasound ecocardiography ...
Contents
A R D THORNTON | 1 |
Physicists and clinicians | 5 |
The Fourier transform properties of an image | 12 |
Copyright | |
48 other sections not shown
Other editions - View all
Common terms and phrases
alveolar amplitude analysis aorta aortic approximately arterial pressure arterial system attenuation value basilar membrane beam blood flow blood pressure C₁ capillary cardiac output circulation clinical cm³ CO₂ cochlea cochlear compartment compliance components computed tomography concentration constant counting rate cross-section cuff decrease detector diameter diastolic distribution effect elastin electrode energy equation filter fluid Fourier transform frame frequency function haemoglobin hair cells halothane heart rate impulse response increase left heart linear linear-attenuation coefficient lung manometer measured medical physics membrane method mmHg muscle normal obtained oxygen P₁ P₂ pacemaker patient peripheral resistance photons physicist physiological pulmonary pulsatile pulse ratio region Rendiconti S.I.F. sample scan scanner segment shown in fig shows signal stroke volume systolic techniques tissues transducer transmural pressure tube ultrasonic V₁ velocity venous system ventilation ventricle ventricular vessel viscoelastic volume wall wave form Windkessel X-ray zero