Elements of X-ray DiffractionThis is a reproduction of a book published before 1923. This book may have occasional imperfections such as missing or blurred pages, poor pictures, errant marks, etc. that were either part of the original artifact, or were introduced by the scanning process. We believe this work is culturally important, and despite the imperfections, have elected to bring it back into print as part of our continuing commitment to the preservation of printed works worldwide. We appreciate your understanding of the imperfections in the preservation process, and hope you enjoy this valuable book. |
From inside the book
Results 1-3 of 82
Page 154
... distance is impressed on the film which will shrink in the same proportion as the distance between a given pair of diffraction lines . If the angular separation 40K of the knife - edges in the camera is known , either by direct ...
... distance is impressed on the film which will shrink in the same proportion as the distance between a given pair of diffraction lines . If the angular separation 40K of the knife - edges in the camera is known , either by direct ...
Page 228
... distance OS 2 3 4 5 6 E S FIG . 8-11 . Use of a stereographic ruler to plot the pole of a reflecting plane on a ... distance OS may be measured . The distance PQ correspond- ing to each distance OS is then calculated from Eqs . ( 8-1 ) ...
... distance OS 2 3 4 5 6 E S FIG . 8-11 . Use of a stereographic ruler to plot the pole of a reflecting plane on a ... distance OS may be measured . The distance PQ correspond- ing to each distance OS is then calculated from Eqs . ( 8-1 ) ...
Page 440
... distance . To ensure that the specimen - to- film distance D is effectively equal for both the inclined- and normal - inci- dence exposures , it is enough to adjust this distance to within ± 1 mm of its nominal value with a distance ...
... distance . To ensure that the specimen - to- film distance D is effectively equal for both the inclined- and normal - inci- dence exposures , it is enough to adjust this distance to within ± 1 mm of its nominal value with a distance ...
Other editions - View all
Common terms and phrases
absorption coefficient absorption edge alloy analysis angle atomic number austenite axis back-reflection Bragg angle Bragg law Bravais lattice calculated camera chart circle composition constant copper atoms cos² counter cubic curve Debye ring Debye-Scherrer decreases determined diffracted beam diffraction lines diffraction pattern diffractometer direction distance electrons elements equation error example face-centered face-centered cubic factor film fluorescent fluorescent radiation given grain hexagonal incident beam indices integrated intensity lattice parameter Laue method martensite measured metal normal obtained Orthorhombic parallel percent phase photograph pinhole plotted pole figure position powder pattern preferred orientation projection reciprocal lattice reciprocal-lattice reflecting planes relative residual stress rhombohedral rotation sample scattering shown in Fig sin² slit solid solution spacing specimen spectrometer sphere spot stereographic substance surface temperature tetragonal thickness tion transmission unit cell values vector voltage wavelength x-ray diffraction x-ray method x-ray tube zero zone