International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 9
Page 455
... BONDING E3509.1 General . Bonding shall be provided where necessary to ensure electrical continuity and the capacity ... jumper on supply side of service and main bonding jumper . The bonding jumper shall not be smaller than the sizes ...
... BONDING E3509.1 General . Bonding shall be provided where necessary to ensure electrical continuity and the capacity ... jumper on supply side of service and main bonding jumper . The bonding jumper shall not be smaller than the sizes ...
Page 456
... bonding . The interior metal wa- ter piping system shall be bonded to the service equipment en- closure , the ... jumper shall be sized in accordance with Table E3503.1 . The points of attach- ment of the bonding jumper ( s ) shall be ...
... bonding . The interior metal wa- ter piping system shall be bonded to the service equipment en- closure , the ... jumper shall be sized in accordance with Table E3503.1 . The points of attach- ment of the bonding jumper ( s ) shall be ...
Page 491
... bonding jumper on load side of service . The equipment bonding jumper on the load side of the service overcurrent devices shall be sized , as a minimum , in ac- cordance with Table E3808.12 , but shall not be required to be larger than ...
... bonding jumper on load side of service . The equipment bonding jumper on the load side of the service overcurrent devices shall be sized , as a minimum , in ac- cordance with Table E3808.12 , but shall not be required to be larger than ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity amperes anchor appliance applied approved ASTM bonding jumper braced wall line branch circuit building official cable ceiling joists clearance common vent comply concrete conduit connected construction dead load Design Required device diameter Douglas fir-larch draft hood drain ducts electrical enclosure exceed FAN NAT fastened feet fireplace fittings fixture floor flue framing furnace grade Ground snow load grounding conductor heating height Hem-fir horizontal installed in accordance insulating concrete form insulation International Building Code INTERNATIONAL RESIDENTIAL CODE joints joists kN/m² length less LINTEL located luminaire material maximum metal minimum nail NAT FAN opening outlet panels permitted piping material pressure protection raceway rafter receptacle reinforcement roof screws Seismic Design Category sheathing slope Southern pine space span Specification Spruce-pine-fir steel structural studs thickness tion tubing Type units valve vent connector venting system vertical wood