International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 90
Page 62
... concrete in accordance with Footnote d . d . Concrete shall be air entrained . Total air content ( percent by volume of concrete ) shall not be less than 5 percent or more than 7 percent . e . See Section R402.2 for minimum cement ...
... concrete in accordance with Footnote d . d . Concrete shall be air entrained . Total air content ( percent by volume of concrete ) shall not be less than 5 percent or more than 7 percent . e . See Section R402.2 for minimum cement ...
Page 72
... Concrete foundation walls . Concrete foundation walls shall be constructed as set forth in Tables R404.1.1 ( 1 ) , R404.1.1 ( 2 ) , R404.1.1 ( 3 ) and R404.1.1 ( 4 ) , and shall also comply with the provisions of this section and the ...
... Concrete foundation walls . Concrete foundation walls shall be constructed as set forth in Tables R404.1.1 ( 1 ) , R404.1.1 ( 2 ) , R404.1.1 ( 3 ) and R404.1.1 ( 4 ) , and shall also comply with the provisions of this section and the ...
Page 167
... concrete form walls for buildings not greater than 60 feet ( 18 288 mm ) in plan di- mensions , and floors not greater than 32 feet ( 9754 mm ) or roofs not greater than 40 feet ( 12 192 mm ) in clear span . Build- ings shall not exceed ...
... concrete form walls for buildings not greater than 60 feet ( 18 288 mm ) in plan di- mensions , and floors not greater than 32 feet ( 9754 mm ) or roofs not greater than 40 feet ( 12 192 mm ) in clear span . Build- ings shall not exceed ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity amperes anchor appliance applied approved ASTM bonding jumper braced wall line branch circuit building official cable ceiling joists clearance common vent comply concrete conduit connected construction dead load Design Required device diameter Douglas fir-larch draft hood drain ducts electrical enclosure exceed FAN NAT fastened feet fireplace fittings fixture floor flue framing furnace grade Ground snow load grounding conductor heating height Hem-fir horizontal installed in accordance insulating concrete form insulation International Building Code INTERNATIONAL RESIDENTIAL CODE joints joists kN/m² length less LINTEL located luminaire material maximum metal minimum nail NAT FAN opening outlet panels permitted piping material pressure protection raceway rafter receptacle reinforcement roof screws Seismic Design Category sheathing slope Southern pine space span Specification Spruce-pine-fir steel structural studs thickness tion tubing Type units valve vent connector venting system vertical wood