International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 84
Page 192
... diameter Staggered 5 - inch - diameter Two Two 1 / 2 - inch - diameter anchor bolts anchor bolts anchor bolts ' 5 / 8 - inch - diameter anchor bolts ' 18 20 36 40 10 16 18 32 36 12 14 18 28 36 14 16 18 9 200 12 16 24 32 10 14 20 28 13 ...
... diameter Staggered 5 - inch - diameter Two Two 1 / 2 - inch - diameter anchor bolts anchor bolts anchor bolts ' 5 / 8 - inch - diameter anchor bolts ' 18 20 36 40 10 16 18 32 36 12 14 18 28 36 14 16 18 9 200 12 16 24 32 10 14 20 28 13 ...
Page 426
... diameter of Section A. 5. The length of Section B shall not be more than 36 inches ( 914 mm ) . 6. The diameter of Section C shall be one pipe size larger than the diameter of Section B. 7. The total length of Section A and Section C ...
... diameter of Section A. 5. The length of Section B shall not be more than 36 inches ( 914 mm ) . 6. The diameter of Section C shall be one pipe size larger than the diameter of Section B. 7. The total length of Section A and Section C ...
Page 546
... diameter vent connector has a maximum capacity of 120,000 Btu per hour ( which is too small for the furnace ) and a 6 - inch diameter vent connector has a maximum vent capacity of 172,000 Btu per hour . Therefore , a 6 - inch diameter ...
... diameter vent connector has a maximum capacity of 120,000 Btu per hour ( which is too small for the furnace ) and a 6 - inch diameter vent connector has a maximum vent capacity of 172,000 Btu per hour . Therefore , a 6 - inch diameter ...
Contents
AE502 Foundation Systems | 61 |
Section | 96 |
EXIT TERMINALS | 549 |
Copyright | |
2 other sections not shown
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists circuit clearance combustion air comply concrete conductors connected construction County Zone dead load diameter Douglas fir-larch draft hood drain ducts equipment exceed fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout gypsum heating height Hem-fir horizontal ICF wall installed in accordance insulating concrete form insulation International Building Code joints kN/mē length less LINTEL listed and labeled load-bearing located luminaire manufacturer's installation instructions masonry heater material maximum metal minimum nail opening outlet permitted pipe piping material plate pound per square pressure R-value raceway reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space Specification Spruce-pine-fir studs thickness tion Type underlayment units valve vent connector vertical wall studs Wood shingles yield strength