International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 26
Page 367
... draft - hood - equipped appliance , the effective area of the vent connector and the gas vent shall be not less than the area of the appliance draft hood outlet , nor greater than seven times the draft hood outlet area . 3. For sizing a gas ...
... draft - hood - equipped appliance , the effective area of the vent connector and the gas vent shall be not less than the area of the appliance draft hood outlet , nor greater than seven times the draft hood outlet area . 3. For sizing a gas ...
Page 371
... draft hood . Where it is determined that a draft hood of special design is needed or preferable for a particular installation , the in- stallation shall be in accordance with the recommenda- tions of the equipment manufacturer and shall ...
... draft hood . Where it is determined that a draft hood of special design is needed or preferable for a particular installation , the in- stallation shall be in accordance with the recommenda- tions of the equipment manufacturer and shall ...
Page 546
... draft hood - equipped appliances to find that a 3 - inch diameter vent connector has a capacity of 37,000 Btu per hour . There- fore , a 3 - inch single - wall metal vent connector may be used with the water heater . For a draft hood ...
... draft hood - equipped appliances to find that a 3 - inch diameter vent connector has a capacity of 37,000 Btu per hour . There- fore , a 3 - inch single - wall metal vent connector may be used with the water heater . For a draft hood ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity amperes anchor appliance applied approved ASTM bonding jumper braced wall line branch circuit building official cable ceiling joists clearance common vent comply concrete conduit connected construction dead load Design Required device diameter Douglas fir-larch draft hood drain ducts electrical enclosure exceed FAN NAT fastened feet fireplace fittings fixture floor flue framing furnace grade Ground snow load grounding conductor heating height Hem-fir horizontal installed in accordance insulating concrete form insulation International Building Code INTERNATIONAL RESIDENTIAL CODE joints joists kN/m² length less LINTEL located luminaire material maximum metal minimum nail NAT FAN opening outlet panels permitted piping material pressure protection raceway rafter receptacle reinforcement roof screws Seismic Design Category sheathing slope Southern pine space span Specification Spruce-pine-fir steel structural studs thickness tion tubing Type units valve vent connector venting system vertical wood