International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 64
Page 82
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and dampproofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
... Drainage and dampproofing / waterproofing . ICF foundation basements shall be drained and dampproofed / waterproofed in accordance with Sections R405 and R406 . SECTION R405 FOUNDATION DRAINAGE R405.1 Concrete or masonry foundations .
Page 417
... drainage piping ; below - grade drains within the building ( building drain ) ; below- and above - grade venting systems ; and piping to the public sewer or private septic system . P3001.2 Protection from freezing . No portion of the ...
... drainage piping ; below - grade drains within the building ( building drain ) ; below- and above - grade venting systems ; and piping to the public sewer or private septic system . P3001.2 Protection from freezing . No portion of the ...
Page 422
International Code Council. SECTION P3005 DRAINAGE SYSTEM P3005.1 Drainage fittings and connections . Changes in di- rection in drainage piping shall be made by the appropriate use of sanitary tees , wyes , sweeps , bends or by a ...
International Code Council. SECTION P3005 DRAINAGE SYSTEM P3005.1 Drainage fittings and connections . Changes in di- rection in drainage piping shall be made by the appropriate use of sanitary tees , wyes , sweeps , bends or by a ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity amperes anchor appliance applied approved ASTM bonding jumper braced wall line branch circuit building official cable ceiling joists clearance common vent comply concrete conduit connected construction dead load Design Required device diameter Douglas fir-larch draft hood drain ducts electrical enclosure exceed FAN NAT fastened feet fireplace fittings fixture floor flue framing furnace grade Ground snow load grounding conductor heating height Hem-fir horizontal installed in accordance insulating concrete form insulation International Building Code INTERNATIONAL RESIDENTIAL CODE joints joists kN/m² length less LINTEL located luminaire material maximum metal minimum nail NAT FAN opening outlet panels permitted piping material pressure protection raceway rafter receptacle reinforcement roof screws Seismic Design Category sheathing slope Southern pine space span Specification Spruce-pine-fir steel structural studs thickness tion tubing Type units valve vent connector venting system vertical wood