International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 90
Page 71
... horizontal insula- tion of frost protected shallow foundations that adjoin a slab - on - ground foundation that does not have a monthly mean temperature maintained at a minimum of 64 ° F ( 18 ° C ) , shall be in accordance with Figure ...
... horizontal insula- tion of frost protected shallow foundations that adjoin a slab - on - ground foundation that does not have a monthly mean temperature maintained at a minimum of 64 ° F ( 18 ° C ) , shall be in accordance with Figure ...
Page 160
... horizontal elements in accordance with the requirements of Section 2.1.8 of ACI 530 / ASCE 5 / TMS 402. Where anchor bolts are used to connect horizontal elements to the tops of col- umns , anchor bolts shall be placed within lateral ...
... horizontal elements in accordance with the requirements of Section 2.1.8 of ACI 530 / ASCE 5 / TMS 402. Where anchor bolts are used to connect horizontal elements to the tops of col- umns , anchor bolts shall be placed within lateral ...
Page 172
... Horizontal steel . Concrete walls with a minimum thickness of 4 inches ( 102 mm ) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches ( 812 mm ) on center with one bar within 12 inches ( 305 mm ) ...
... Horizontal steel . Concrete walls with a minimum thickness of 4 inches ( 102 mm ) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches ( 812 mm ) on center with one bar within 12 inches ( 305 mm ) ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity amperes anchor appliance applied approved ASTM bonding jumper braced wall line branch circuit building official cable ceiling joists clearance common vent comply concrete conduit connected construction dead load Design Required device diameter Douglas fir-larch draft hood drain ducts electrical enclosure exceed FAN NAT fastened feet fireplace fittings fixture floor flue framing furnace grade Ground snow load grounding conductor heating height Hem-fir horizontal installed in accordance insulating concrete form insulation International Building Code INTERNATIONAL RESIDENTIAL CODE joints joists kN/m² length less LINTEL located luminaire material maximum metal minimum nail NAT FAN opening outlet panels permitted piping material pressure protection raceway rafter receptacle reinforcement roof screws Seismic Design Category sheathing slope Southern pine space span Specification Spruce-pine-fir steel structural studs thickness tion tubing Type units valve vent connector venting system vertical wood