International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 57
Page 214
... rafter . At all valleys and hips there shall be a valley or hip rafter not less than 2 - inch ( 51 mm ) nominal thickness and not less in depth than the cut end of the rafter . Hip and valley rafters shall be supported at the ridge by a ...
... rafter . At all valleys and hips there shall be a valley or hip rafter not less than 2 - inch ( 51 mm ) nominal thickness and not less in depth than the cut end of the rafter . Hip and valley rafters shall be supported at the ridge by a ...
Page 233
... rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls , such as rafter ties , is provided at that location . When ...
... rafter spans assume that ceiling joists are located at the bottom of the attic space or that some other method of resisting the outward push of the rafters on the bearing walls , such as rafter ties , is provided at that location . When ...
Page 241
... Rafter to ceiling joist NUMBER AND SIZE OF FASTENERS SPACING OF FASTENERS 2 No. 10 screws Each joist No. 8 screws 2 ... RAFTER SUPPORT BRACE RAFTER BOTTOM FLANGE BRACING ( FLAT STRAP , 350S162-33 MIL C - SECTION , OR TRACK SECTION ) ...
... Rafter to ceiling joist NUMBER AND SIZE OF FASTENERS SPACING OF FASTENERS 2 No. 10 screws Each joist No. 8 screws 2 ... RAFTER SUPPORT BRACE RAFTER BOTTOM FLANGE BRACING ( FLAT STRAP , 350S162-33 MIL C - SECTION , OR TRACK SECTION ) ...
Contents
AE502 Foundation Systems | 61 |
Section | 96 |
EXIT TERMINALS | 549 |
Copyright | |
2 other sections not shown
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists circuit clearance combustion air comply concrete conductors connected construction County Zone dead load diameter Douglas fir-larch draft hood drain ducts equipment exceed fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout gypsum heating height Hem-fir horizontal ICF wall installed in accordance insulating concrete form insulation International Building Code joints kN/mē length less LINTEL listed and labeled load-bearing located luminaire manufacturer's installation instructions masonry heater material maximum metal minimum nail opening outlet permitted pipe piping material plate pound per square pressure R-value raceway reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space Specification Spruce-pine-fir studs thickness tion Type underlayment units valve vent connector vertical wall studs Wood shingles yield strength