Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 16
Page 3-187
... ANSI B16.4 Cast Iron Pipe Flanges and Flanged Fittings ANSI B16.1 Malleable Iron Malleable Iron Threaded Fittings , Class 150 and 300 ANSI B16.3 Steel Factory - made Wrought Steel Buttweld Fittings .. Buttwelding Ends for Pipe , Valves ...
... ANSI B16.4 Cast Iron Pipe Flanges and Flanged Fittings ANSI B16.1 Malleable Iron Malleable Iron Threaded Fittings , Class 150 and 300 ANSI B16.3 Steel Factory - made Wrought Steel Buttweld Fittings .. Buttwelding Ends for Pipe , Valves ...
Page 3-315
... ANSI B16.3-1985 , Malleable Iron Threaded Fittings , Class 150 and 300 ANSI B16.4-1985 , Cast Iron Threaded Fittings , Classes 125 and 250 ANSI B16.5-1988 , Pipe Flanges and Flanged Fittings ANSI B16.9-1986 , Factory - Made Wrought ...
... ANSI B16.3-1985 , Malleable Iron Threaded Fittings , Class 150 and 300 ANSI B16.4-1985 , Cast Iron Threaded Fittings , Classes 125 and 250 ANSI B16.5-1988 , Pipe Flanges and Flanged Fittings ANSI B16.9-1986 , Factory - Made Wrought ...
Page 3-458
... ANSI B16.5-1988 , Pipe Flanges and Flanged Fittings ANSI B16.9-1986 , Factory - Made Wrought Steel Buttwelding Fittings ANSI B16.11-1991 , Forged Fittings , Socket Welding and Threaded ANSI B16.18-1984 , Cast Copper Alloy Solder - Joint ...
... ANSI B16.5-1988 , Pipe Flanges and Flanged Fittings ANSI B16.9-1986 , Factory - Made Wrought Steel Buttwelding Fittings ANSI B16.11-1991 , Forged Fittings , Socket Welding and Threaded ANSI B16.18-1984 , Cast Copper Alloy Solder - Joint ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood