Page 3-119
... ( Table 7-7 - W - A ) , the time assigned to the framing members ( Table 7-7 - W - C ) , and the time assigned for other protective measures , such as insulation ( Table 7-7 - W - D ) . The membrane on the unexposed side shall not be ...
... ( Table 7-7 - W - A ) , the time assigned to the framing members ( Table 7-7 - W - C ) , and the time assigned for other protective measures , such as insulation ( Table 7-7 - W - D ) . The membrane on the unexposed side shall not be ...
Page 3-300
... Table 6-5.3.2 ( b ) . Table 6-5.3.2 ( b ) Number of Sprinklers - Greater than 12 ft Separations Steel Copper 2/2 in . 3 in . 15 sprinklers 30 sprinklers 22 in . 3 in . 20 sprinklers 35 sprinklers 32 in . 60 sprinklers 32 in . 65 ...
... Table 6-5.3.2 ( b ) . Table 6-5.3.2 ( b ) Number of Sprinklers - Greater than 12 ft Separations Steel Copper 2/2 in . 3 in . 15 sprinklers 30 sprinklers 22 in . 3 in . 20 sprinklers 35 sprinklers 32 in . 60 sprinklers 32 in . 65 ...
Page 3-442
... Table 5-10.1 , the increased fric- tion loss shall be included in hydraulic calculations . 5-10.2 Adjustments . Table 5-10.1 shall be used with Hazen - Williams C = 120 only . For other values of C , the values in Table 5-10.1 shall be ...
... Table 5-10.1 , the increased fric- tion loss shall be included in hydraulic calculations . 5-10.2 Adjustments . Table 5-10.1 shall be used with Hazen - Williams C = 120 only . For other values of C , the values in Table 5-10.1 shall be ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood