Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 83
Page 3-118
... units with 4 or 5 cells in wall thickness , 40 % solid 4.00 CLAY TILE 4 - inch unit ; 1 cell in wall thickness , 40 % solid2.3 6 - inch unit ; I cell in wall thickness , 30 % solid2.3 6 - inch unit ; 2 cell in wall thickness , 45 ...
... units with 4 or 5 cells in wall thickness , 40 % solid 4.00 CLAY TILE 4 - inch unit ; 1 cell in wall thickness , 40 % solid2.3 6 - inch unit ; I cell in wall thickness , 30 % solid2.3 6 - inch unit ; 2 cell in wall thickness , 45 ...
Page 3-545
... Units Based on the Standards of the Cedar Shake and Shingle Bureau SECTION 15.407- DEFINITION Shingle hip and ridge units are manufactured from No. 1 or No. 2 grade shingles that have one edge sawn on a bevel and fastened together to ...
... Units Based on the Standards of the Cedar Shake and Shingle Bureau SECTION 15.407- DEFINITION Shingle hip and ridge units are manufactured from No. 1 or No. 2 grade shingles that have one edge sawn on a bevel and fastened together to ...
Page 3-613
... units are the manufacturer's designated dimensions . Nominal dimensions of modular - size units are equal to the standard dimensions plus 3/8 inch ( 9.5 mm ) , the thickness of one standard mortar joint . Nominal dimensions of ...
... units are the manufacturer's designated dimensions . Nominal dimensions of modular - size units are equal to the standard dimensions plus 3/8 inch ( 9.5 mm ) , the thickness of one standard mortar joint . Nominal dimensions of ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood