... alarm on the premises within 5 minutes after such flow begins . 2-9.2 Waterflow Detecting Devices . 2-9.2.1 Wet Pipe Systems . The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed ...
... alarm on the premises within 5 minutes after such flow begins . 2-9.2 Waterflow Detecting Devices . 2-9.2.1 Wet Pipe Systems . The alarm apparatus for a wet pipe system shall consist of a listed alarm check valve or other listed ...
Page 3-273
... Alarms . 4-6.1.1 * Waterflow Alarms . 4-6.1.1.1 Local waterflow alarms shall be provided on all sprinkler systems having more than 20 sprinklers . 4-6.1.1.2 On each alarm check valve used under condi- tions of variable water pressure ...
... Alarms . 4-6.1.1 * Waterflow Alarms . 4-6.1.1.1 Local waterflow alarms shall be provided on all sprinkler systems having more than 20 sprinklers . 4-6.1.1.2 On each alarm check valve used under condi- tions of variable water pressure ...
Page 3-274
... Alarm Attachments When a fire must be fought internally due to the height of a building , the following additional alarm apparatus shall be provided : ( a ) When each sprinkler system on each floor is equipped with a separate waterflow ...
... Alarm Attachments When a fire must be fought internally due to the height of a building , the following additional alarm apparatus shall be provided : ( a ) When each sprinkler system on each floor is equipped with a separate waterflow ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood