Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 87
Page 3-20
... ASSEMBLY In obtaining a restrained assembly classification , the following conditions shall be met : 1. The specimen shall have sustained the applied load during the classification period without developing unexposed surface conditions ...
... ASSEMBLY In obtaining a restrained assembly classification , the following conditions shall be met : 1. The specimen shall have sustained the applied load during the classification period without developing unexposed surface conditions ...
Page 3-51
... assemblies , for use in wall openings to retard the passage of fire . Test methods in this standard are intended to evaluate the ability of a window or other light - transmitting assembly to remain in an opening during a predetermined ...
... assemblies , for use in wall openings to retard the passage of fire . Test methods in this standard are intended to evaluate the ability of a window or other light - transmitting assembly to remain in an opening during a predetermined ...
Page 3-52
... assembly shall be subjected to the impact , erosion and cooling effects of the hose stream . The hose stream shall ... assembly . If impossible to be so located , the nozzle may be on a line deviating not to exceed 30 degrees from the ...
... assembly shall be subjected to the impact , erosion and cooling effects of the hose stream . The hose stream shall ... assembly . If impossible to be so located , the nozzle may be on a line deviating not to exceed 30 degrees from the ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood