Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 87
Page 3-235
... Ceiling Or Flooring For SI Units : 1 in . = 25.4 mm . Figure 4-4.1.3.4 Arrangement of sprinklers under two sets of open joists no sheathing on lower joists . 4-4.1.3.4 Double Joist Obstructions . Where there are two sets of joists under ...
... Ceiling Or Flooring For SI Units : 1 in . = 25.4 mm . Figure 4-4.1.3.4 Arrangement of sprinklers under two sets of open joists no sheathing on lower joists . 4-4.1.3.4 Double Joist Obstructions . Where there are two sets of joists under ...
Page 3-503
International Conference of Building Officials. Ceiling Obstruction Ceiling Not to Exceed Maximum Permitted ( see 2-5.1.7.1 and 2-5.1.7.2 ) Maximum Distance Deflector Above Bottom of Ceiling Obstruction Distance From Near Side of Ceiling ...
International Conference of Building Officials. Ceiling Obstruction Ceiling Not to Exceed Maximum Permitted ( see 2-5.1.7.1 and 2-5.1.7.2 ) Maximum Distance Deflector Above Bottom of Ceiling Obstruction Distance From Near Side of Ceiling ...
Page 3-787
... ceiling system . The attachment device shall have a capacity of 100 percent of the lighting fixture weight acting in ... ceiling suspension system for direct support . SECTION 25.214― MECHANICAL SERVICES Ceiling - mounted air terminals ...
... ceiling system . The attachment device shall have a capacity of 100 percent of the lighting fixture weight acting in ... ceiling suspension system for direct support . SECTION 25.214― MECHANICAL SERVICES Ceiling - mounted air terminals ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood