Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 50
Page 3-567
... cements using slag or pozzolan , or both , with portland cement or portland cement clinker or slag with lime . The types of blended cement covered by this specification are as follows : Portland Blast - furnace Slag Cement - One type ...
... cements using slag or pozzolan , or both , with portland cement or portland cement clinker or slag with lime . The types of blended cement covered by this specification are as follows : Portland Blast - furnace Slag Cement - One type ...
Page 3-568
... CEMENTS , TYPE SA , is slag cement Type S , except that suffi- cient air - entraining addition , as specified in Section 19.107 , has been used so that the resulting product complies with the air content of mortar requirements given in ...
... CEMENTS , TYPE SA , is slag cement Type S , except that suffi- cient air - entraining addition , as specified in Section 19.107 , has been used so that the resulting product complies with the air content of mortar requirements given in ...
Page 3-569
... cement . SLAG CEMENT , TYPE S , is a blended hydraulic cement consisting mostly of an intimate and uniform blend of granulated blast - furnace slag and portland cement , or hydrated lime , or both , in which the slag constituent is at ...
... cement . SLAG CEMENT , TYPE S , is a blended hydraulic cement consisting mostly of an intimate and uniform blend of granulated blast - furnace slag and portland cement , or hydrated lime , or both , in which the slag constituent is at ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood