Page 3-20
... classification , the following conditions shall be met : 1. The specimen shall have sustained the applied load during the classification period without developing unexposed surface conditions which will ignite cotton waste . 2 ...
... classification , the following conditions shall be met : 1. The specimen shall have sustained the applied load during the classification period without developing unexposed surface conditions which will ignite cotton waste . 2 ...
Page 3-22
... classification period . 2. The specimen shall have achieved a fire - endurance classification on the basis of the tempera- ture criteria specified in Section 7.128 , Item 3 or 4 , of one half the classification of the assembly , or one ...
... classification period . 2. The specimen shall have achieved a fire - endurance classification on the basis of the tempera- ture criteria specified in Section 7.128 , Item 3 or 4 , of one half the classification of the assembly , or one ...
Page 3-223
... classification , and sprinklers in the danger zone of the intermediate temperature classification . ( b ) Sprinklers located within 12 in . ( 305 mm ) to one side or 30 in . ( 762 mm ) above an uncovered steam main , heat- ing coil , or ...
... classification , and sprinklers in the danger zone of the intermediate temperature classification . ( b ) Sprinklers located within 12 in . ( 305 mm ) to one side or 30 in . ( 762 mm ) above an uncovered steam main , heat- ing coil , or ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood