Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 52
Page 3-18
... column loading at any time and may be used at the discretion of the testing laboratory to evaluate steel column protections that are not required by design to carry any of the column load . SECTION 7.119 — SIZE AND CHARACTER OF SAMPLE ...
... column loading at any time and may be used at the discretion of the testing laboratory to evaluate steel column protections that are not required by design to carry any of the column load . SECTION 7.119 — SIZE AND CHARACTER OF SAMPLE ...
Page 3-65
... columns can be determined from Figure 7-7 - S - 4 for various thicknesses of gypsum wallboard as a function of the weight - to - heated - perimeter ratio ( W / D ) of the column . For structural steel columns with weight - to - heated ...
... columns can be determined from Figure 7-7 - S - 4 for various thicknesses of gypsum wallboard as a function of the weight - to - heated - perimeter ratio ( W / D ) of the column . For structural steel columns with weight - to - heated ...
Page 3-67
... column , pounds per linear foot ( kg / m ) . Pc = concrete density , pounds per cubic foot ( kg / m3 ) . For wide - flange steel columns completely encased in concrete with all reentrant spaces filled ( Figure 7-7 - S - 6 , Detail C ) ...
... column , pounds per linear foot ( kg / m ) . Pc = concrete density , pounds per cubic foot ( kg / m3 ) . For wide - flange steel columns completely encased in concrete with all reentrant spaces filled ( Figure 7-7 - S - 6 , Detail C ) ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood