Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 87
Page 3-204
... devices and of the sprinklers . 3-3.1.3 Pressure Gauges . Listed pressure gauges con- forming to 4-6.3.2 shall be installed as follows : ( a ) Above and below preaction valve and below deluge valve . ( b ) On air supply to preaction and ...
... devices and of the sprinklers . 3-3.1.3 Pressure Gauges . Listed pressure gauges con- forming to 4-6.3.2 shall be installed as follows : ( a ) Above and below preaction valve and below deluge valve . ( b ) On air supply to preaction and ...
Page 3-205
... Devices for Test Purposes and Testing Appara- tus . 3-3.1.7.1 When detection devices installed in circuits are located where not readily accessible , an additional detec- tion device shall be provided on each circuit for test pur- poses ...
... Devices for Test Purposes and Testing Appara- tus . 3-3.1.7.1 When detection devices installed in circuits are located where not readily accessible , an additional detec- tion device shall be provided on each circuit for test pur- poses ...
Page 3-512
... devices is applicable where such devices are permitted by the building official for installation on existing apartment houses and hotels in conformance with Appendix Section 3412.1 of this code . SECTION 10.302 — INSTRUCTIONS ...
... devices is applicable where such devices are permitted by the building official for installation on existing apartment houses and hotels in conformance with Appendix Section 3412.1 of this code . SECTION 10.302 — INSTRUCTIONS ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood