Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 39
Page 3-202
... dry pipe valve and quick - opening device are set , except where design features of the particular quick - opening device make these require- ments unnecessary . 3-2.4.3 A soft disc globe or angle valve shall be installed in the ...
... dry pipe valve and quick - opening device are set , except where design features of the particular quick - opening device make these require- ments unnecessary . 3-2.4.3 A soft disc globe or angle valve shall be installed in the ...
Page 3-207
... dry pipe valves installed in parallel for combined systems , standard trimmings not shown . 3-4.2.2 Each dry pipe valve shall be provided with a listed tripping device actuated by the detection system . Dry pipe valves shall be cross ...
... dry pipe valves installed in parallel for combined systems , standard trimmings not shown . 3-4.2.2 Each dry pipe valve shall be provided with a listed tripping device actuated by the detection system . Dry pipe valves shall be cross ...
Page 3-332
... piping due to accidental tripping of dry pipe valves in cold storage rooms , a deluge automatic water control valve may be used on the supply side of the dry pipe valve . When this combination is employed : ( a ) Dry systems may be ...
... piping due to accidental tripping of dry pipe valves in cold storage rooms , a deluge automatic water control valve may be used on the supply side of the dry pipe valve . When this combination is employed : ( a ) Dry systems may be ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood