... feet ( 15 240 mm ) wide or less and 30 feet ( 9144 mm ) high or less ; and the frame or modified frame styles shall be used for openings over 50 feet ( 15 240 mm ) in width or 30 feet ( 9144 mm ) in height . Curtain installations in new ...
... feet ( 15 240 mm ) wide or less and 30 feet ( 9144 mm ) high or less ; and the frame or modified frame styles shall be used for openings over 50 feet ( 15 240 mm ) in width or 30 feet ( 9144 mm ) in height . Curtain installations in new ...
Page 3-7
... feet ( 1219 mm ) for frame and modified frame styles of semirigid construction , or at least 6 feet ( 1829 mm ) for all other styles . These smoke pockets shall extend vertically from the stage floor to a point 1 to 3 feet ( 305 to 914 ...
... feet ( 1219 mm ) for frame and modified frame styles of semirigid construction , or at least 6 feet ( 1829 mm ) for all other styles . These smoke pockets shall extend vertically from the stage floor to a point 1 to 3 feet ( 305 to 914 ...
Page 3-133
... feet ( 1372 mm ) . SECTION 8.107 — INTERPRETATION OF RESULTS - The flame - spread index ( FSI ) shall be determined ... feet ( 3048 mm ) in 21/2 minutes and then recedes . The area is calculated as if the flame had spread to 10 feet ...
... feet ( 1372 mm ) . SECTION 8.107 — INTERPRETATION OF RESULTS - The flame - spread index ( FSI ) shall be determined ... feet ( 3048 mm ) in 21/2 minutes and then recedes . The area is calculated as if the flame had spread to 10 feet ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood