Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 84
Page 3-21
... floor or roof units intended for use in spans greater than those tested , the average temperature recorded by all thermocouples located on any one span of the floor or roof units shall not have exceeded 1,100 ° F . ( 593 ° C . ) during ...
... floor or roof units intended for use in spans greater than those tested , the average temperature recorded by all thermocouples located on any one span of the floor or roof units shall not have exceeded 1,100 ° F . ( 593 ° C . ) during ...
Page 3-120
... FLOORING OR ROOFING Hard or softwood flooring on building paper . Resilient flooring , parquet floor , felted - synthetic- fiber floor coverings , carpeting or ceramic tile on 5 / 8 - inch - thick ( 15.9 mm ) panel - type underlay ...
... FLOORING OR ROOFING Hard or softwood flooring on building paper . Resilient flooring , parquet floor , felted - synthetic- fiber floor coverings , carpeting or ceramic tile on 5 / 8 - inch - thick ( 15.9 mm ) panel - type underlay ...
Page 3-799
... Floor- to - floor height ( unfinished / unprotected ) shall be 12 feet ± 2 inches ( 3658 mm ± 51 mm ) . Floors and roof shall be of reinforced concrete or similar construction supported with columns . The first - floor slab shall be 12 ...
... Floor- to - floor height ( unfinished / unprotected ) shall be 12 feet ± 2 inches ( 3658 mm ± 51 mm ) . Floors and roof shall be of reinforced concrete or similar construction supported with columns . The first - floor slab shall be 12 ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood