Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 83
Page 3-153
... heat release shall be derived by taking the measured maximum rate of heat release and subtracting the burner output . Textile wall coverings which fail to meet the criteria of Section 8.211 may be judged to perform satisfactorily when ...
... heat release shall be derived by taking the measured maximum rate of heat release and subtracting the burner output . Textile wall coverings which fail to meet the criteria of Section 8.211 may be judged to perform satisfactorily when ...
Page 3-552
... HEAT VENTS Standard of the International Conference of Building Officials See Sections 906.1 , 906.4 and 1501.1 , Uniform Building Code SECTION 15.701 - SCOPE 15.701.1 General . This standard applies to thermally activated , automatic ...
... HEAT VENTS Standard of the International Conference of Building Officials See Sections 906.1 , 906.4 and 1501.1 , Uniform Building Code SECTION 15.701 - SCOPE 15.701.1 General . This standard applies to thermally activated , automatic ...
Page 3-789
... HEAT OF BUILDING MATERIALS Test Standard of the International Conference of Building Officials See Sections 601.3 , 2602.4 and 2602.5.2 , Uniform Building Code SECTION 26.101 SCOPE - 26.101.1 General . This method of test defines a ...
... HEAT OF BUILDING MATERIALS Test Standard of the International Conference of Building Officials See Sections 601.3 , 2602.4 and 2602.5.2 , Uniform Building Code SECTION 26.101 SCOPE - 26.101.1 General . This method of test defines a ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood