Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 32
Page 3-294
... hydraulically most demanding area is being used . A minimum of two additional sets of calculations shall be submitted to demonstrate peaking of demand area friction loss when compared to areas immediately adjacent on either side along ...
... hydraulically most demanding area is being used . A minimum of two additional sets of calculations shall be submitted to demonstrate peaking of demand area friction loss when compared to areas immediately adjacent on either side along ...
Page 3-396
... hydraulically most demanding area . A - 6-4.4.3 ( b ) This subsection assumes a ceiling con- structed so as to ... hydraulically most remote , additional calculations should be submitted . The most distant area is not necessarily the ...
... hydraulically most demanding area . A - 6-4.4.3 ( b ) This subsection assumes a ceiling con- structed so as to ... hydraulically most remote , additional calculations should be submitted . The most distant area is not necessarily the ...
Page 3-442
... hydraulically calculated sprinkler demand or 150 gpm ( 568 L / min ) for Light Hazard Occupancies , or by 500 gpm ( 1893 L / min ) for Ordinary Hazard Occupancies . 5-9.1.3.3 Where an existing standpipe system having standpipes with a ...
... hydraulically calculated sprinkler demand or 150 gpm ( 568 L / min ) for Light Hazard Occupancies , or by 500 gpm ( 1893 L / min ) for Ordinary Hazard Occupancies . 5-9.1.3.3 Where an existing standpipe system having standpipes with a ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood