Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 74
Page 3-536
... inches , 9 inches and 12 inches ( 191 mm , 229 mm and 305 mm ) from the butt in the 15 - inch , 18 - inch and 24 - inch ( 380 mm , 455 mm and 610 mm ) lengths , respectively , of the No. 2 grade taper - sawn shakes . In the same product ...
... inches , 9 inches and 12 inches ( 191 mm , 229 mm and 305 mm ) from the butt in the 15 - inch , 18 - inch and 24 - inch ( 380 mm , 455 mm and 610 mm ) lengths , respectively , of the No. 2 grade taper - sawn shakes . In the same product ...
Page 3-710
... inches ( 57 mm ) in width . Shims are permitted . Synthetic shims shall completely fill kerfs or voids ; shall ... inches ( 38 mm ) across the grain , and knotholes up to 1 inch ( 25 mm ) measured across the grain . An occasional ...
... inches ( 57 mm ) in width . Shims are permitted . Synthetic shims shall completely fill kerfs or voids ; shall ... inches ( 38 mm ) across the grain , and knotholes up to 1 inch ( 25 mm ) measured across the grain . An occasional ...
Page 3-732
... inch ( 4.8 mm ) No crossband laps adjacent to faces No more than a total of 2 of any combination of the following : Knothole in D veneer over 21/2 inches ( 64 mm ) but not over 3 inches ( 76 mm ) Split in D veneer over 1/2 inch ( 13 mm ) ...
... inch ( 4.8 mm ) No crossband laps adjacent to faces No more than a total of 2 of any combination of the following : Knothole in D veneer over 21/2 inches ( 64 mm ) but not over 3 inches ( 76 mm ) Split in D veneer over 1/2 inch ( 13 mm ) ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
99 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet Figure fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knots length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical water supply weight welding width wood