Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 46
Page 3-131
... inches ( 5 mm by 51 mm ) The rods or bars shall span the width of the tunnel . Rods shall be placed approximately 2 inches ( 51 mm ) from each end of each panel and at approximately 2 - foot ( 610 mm ) intervals starting with the fire ...
... inches ( 5 mm by 51 mm ) The rods or bars shall span the width of the tunnel . Rods shall be placed approximately 2 inches ( 51 mm ) from each end of each panel and at approximately 2 - foot ( 610 mm ) intervals starting with the fire ...
Page 3-671
... inches ( 102 mm ) wide is classified as “ Structural Light Framing , " " Light Framing ” and " Studs . " Dimension ... ( 51 to 102 mm ) Thick , 2 to 4 Inches ( 51 to 102 mm ) Wide Grade Name ( and Abbreviation ) Select Structural ( Sel Str ) ...
... inches ( 102 mm ) wide is classified as “ Structural Light Framing , " " Light Framing ” and " Studs . " Dimension ... ( 51 to 102 mm ) Thick , 2 to 4 Inches ( 51 to 102 mm ) Wide Grade Name ( and Abbreviation ) Select Structural ( Sel Str ) ...
Page 3-673
... inches ( 51 mm to 102 mm ) thick , 2 inches to 4 inches ( 51 mm to 102 mm ) wide : Characteristics permitted and limiting provisions shall be : Checks Seasoning checks not limited . Through checks at ends are limited as splits . Grain ...
... inches ( 51 mm to 102 mm ) thick , 2 inches to 4 inches ( 51 mm to 102 mm ) wide : Characteristics permitted and limiting provisions shall be : Checks Seasoning checks not limited . Through checks at ends are limited as splits . Grain ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood