... minimum of two vertical seams shall be subjected to the standard fire test specified in U.B.C. Standard 7-1 as applicable to nonbearing walls and parti- tions for a period of 30 minutes . Surface temperature measurements need not be ...
... minimum of two vertical seams shall be subjected to the standard fire test specified in U.B.C. Standard 7-1 as applicable to nonbearing walls and parti- tions for a period of 30 minutes . Surface temperature measurements need not be ...
Page 3-99
... MINIMUM CONCRETE COVER REQUIREMENTS 7.709.1 Slabs . The minimum thickness of concrete cover to the positive moment reinforcement is given in Table 7-7 - C - D for reinforced concrete and Table 7-7 - C - E for prestressed concrete ...
... MINIMUM CONCRETE COVER REQUIREMENTS 7.709.1 Slabs . The minimum thickness of concrete cover to the positive moment reinforcement is given in Table 7-7 - C - D for reinforced concrete and Table 7-7 - C - E for prestressed concrete ...
Page 3-103
... MINIMUM SIZES OF CONCRETE COLUMNS MINIMUM COLUMN DIMENSION ( INCHES ) FOR FIRE - RESISTANCE RATING OF TYPE OF CONCRETE Siliceous Carbonate Sand - lightweight 1 Hr . 888 11/2 Hr . 8 8 8 600 Wythe of Sand - Lightweight Concrete , in ...
... MINIMUM SIZES OF CONCRETE COLUMNS MINIMUM COLUMN DIMENSION ( INCHES ) FOR FIRE - RESISTANCE RATING OF TYPE OF CONCRETE Siliceous Carbonate Sand - lightweight 1 Hr . 888 11/2 Hr . 8 8 8 600 Wythe of Sand - Lightweight Concrete , in ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood