... OPERATION The door shall be power operated , be capable of manual operation in the event of power failure and be self - closing or smoke - detector - activated automatic closing . The door's power supply shall be capable of being ...
... OPERATION The door shall be power operated , be capable of manual operation in the event of power failure and be self - closing or smoke - detector - activated automatic closing . The door's power supply shall be capable of being ...
Page 3-176
... Operation of the detection system actuates trip- ping devices that open dry pipe valves simultaneously and without loss of air pressure in the system . Operation of the detection system also opens listed air exhaust valves at the end of ...
... Operation of the detection system actuates trip- ping devices that open dry pipe valves simultaneously and without loss of air pressure in the system . Operation of the detection system also opens listed air exhaust valves at the end of ...
Page 3-507
... operation or number of cycles shall be three to five per minute . On sliding doors with a swing - out section ... operation without failure or excessive wear of parts . The release mecha- nisms and disconnect switches of the swinging ...
... operation or number of cycles shall be three to five per minute . On sliding doors with a swing - out section ... operation without failure or excessive wear of parts . The release mecha- nisms and disconnect switches of the swinging ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood