Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 66
Page 3-708
... Panels , other than unsanded and touch - sanded panels , with span ratings which are produced with face and back veneers of the same species group shall be classified as being of that species group . Touch - sanded panels without span ...
... Panels , other than unsanded and touch - sanded panels , with span ratings which are produced with face and back veneers of the same species group shall be classified as being of that species group . Touch - sanded panels without span ...
Page 3-717
... panels ) shall be tested for maximum bending moment both along and across the major panel axis according to the procedures of Section 23.218 . The control value for each panel direction will be the minimum observed value , or the sample ...
... panels ) shall be tested for maximum bending moment both along and across the major panel axis according to the procedures of Section 23.218 . The control value for each panel direction will be the minimum observed value , or the sample ...
Page 3-718
... panels shall not be ac- cepted . If reinspection establishes that a disputed item is 5 percent or less below grade or out of dimensional tolerance , it passes the reinspection . In addition to the above 5 percent grade and di- mensional ...
... panels shall not be ac- cepted . If reinspection establishes that a disputed item is 5 percent or less below grade or out of dimensional tolerance , it passes the reinspection . In addition to the above 5 percent grade and di- mensional ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood