Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 3
Page 3-554
... plasticity index . SECTION 18.102 APPARATUS Apparatus of an approved type shall be used to perform the following tests and procedures : Prepara- tion of soil samples , liquid limit test , plastic limit test and particle - size analysis ...
... plasticity index . SECTION 18.102 APPARATUS Apparatus of an approved type shall be used to perform the following tests and procedures : Prepara- tion of soil samples , liquid limit test , plastic limit test and particle - size analysis ...
Page 3-555
... plasticity index . Determine the cumulative particle - size distribution of the fraction coarser than the No. 200 ... plasticity index of a portion of the test sample passing the No. 40 ( 425 μm ) sieve in accordance with approved ...
... plasticity index . Determine the cumulative particle - size distribution of the fraction coarser than the No. 200 ... plasticity index of a portion of the test sample passing the No. 40 ( 425 μm ) sieve in accordance with approved ...
Page 3-558
... plasticity index less than 4 Atterberg limits plot below " A " line and plasticity index greater than 7 Си = Atterberg limits plotting in hatched area are borderline clas- sifications re- quiring use of dual symbols D60 / D10 Greater ...
... plasticity index less than 4 Atterberg limits plot below " A " line and plasticity index greater than 7 Си = Atterberg limits plotting in hatched area are borderline clas- sifications re- quiring use of dual symbols D60 / D10 Greater ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood