Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 42
Page 3-220
... sq ft ( 4831 m2 ) 52,000 sq ft ( 4831 m2 ) 25,000 sq ft ( 2323 m2 ) 40,000 sq ft ( 3716 m2 ) 40,000 sq ft ( 3716 m2 ) The floor area occupied by mezzanines shall not be included in the above area . Exception No. 2 : When single systems ...
... sq ft ( 4831 m2 ) 52,000 sq ft ( 4831 m2 ) 25,000 sq ft ( 2323 m2 ) 40,000 sq ft ( 3716 m2 ) 40,000 sq ft ( 3716 m2 ) The floor area occupied by mezzanines shall not be included in the above area . Exception No. 2 : When single systems ...
Page 3-222
... ft ) * Unobstructed Construction ' 2252 130 100 100 130 100 Noncombustible Obstructed Con- struction 2252 130 100 ... sq ft per sprinkler . Note 3 : For light combustible framing members spaced less than 3 ft on center , maximum spacing ...
... ft ) * Unobstructed Construction ' 2252 130 100 100 130 100 Noncombustible Obstructed Con- struction 2252 130 100 ... sq ft per sprinkler . Note 3 : For light combustible framing members spaced less than 3 ft on center , maximum spacing ...
Page 3-281
... sq ft ( 139 m2 ) used for Light and Ordinary Hazard Occupan- cies , the density for 1500 sq ft ( 139 m2 ) shall be used . For areas of sprinkler operation less than 2500 sq ft ( 232 m2 ) for Extra Hazard Occupancies , the density for 2500 ...
... sq ft ( 139 m2 ) used for Light and Ordinary Hazard Occupan- cies , the density for 1500 sq ft ( 139 m2 ) shall be used . For areas of sprinkler operation less than 2500 sq ft ( 232 m2 ) for Extra Hazard Occupancies , the density for 2500 ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood