Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 32
Page 3-414
International Conference of Building Officials. Dry Standpipe . A standpipe system designed to have piping contain water only when the system is being uti- lized . ( See Chapter 3. ) Feed Main . That portion of a standpipe system that ...
International Conference of Building Officials. Dry Standpipe . A standpipe system designed to have piping contain water only when the system is being uti- lized . ( See Chapter 3. ) Feed Main . That portion of a standpipe system that ...
Page 3-431
... system , class of system , and special requirements . 3-1.2 Spacing and location of standpipes and hose con- nections shall be in accordance with Chapter 5 . 3-1.3 Standpipe and hose systems not required by the authority having ...
... system , class of system , and special requirements . 3-1.2 Spacing and location of standpipes and hose con- nections shall be in accordance with Chapter 5 . 3-1.3 Standpipe and hose systems not required by the authority having ...
Page 3-432
... standpipe systems require water from a fire department pumper ( or the like ) to be pumped into the system to sup- ply the system demand . 3-3 Classes of Standpipe Systems . 3-3.1 Class I Systems . A Class I standpipe system shall ...
... standpipe systems require water from a fire department pumper ( or the like ) to be pumped into the system to sup- ply the system demand . 3-3 Classes of Standpipe Systems . 3-3.1 Class I Systems . A Class I standpipe system shall ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood