Uniform Building Code, Volume 3International Conference of Building Officials, 1994 - Building laws |
From inside the book
Results 1-3 of 54
Page 3-180
... Storage and Handling of Liquefied Petroleum Gases ; NFPA 81 , Standard for Fur Storage , Fumigation and Cleaning ; NFPA 231 , Standard for General Storage ; NFPA 231C , Standard for Rack Storage of Materials ; NFPA 231D , Standard for ...
... Storage and Handling of Liquefied Petroleum Gases ; NFPA 81 , Standard for Fur Storage , Fumigation and Cleaning ; NFPA 231 , Standard for General Storage ; NFPA 231C , Standard for Rack Storage of Materials ; NFPA 231D , Standard for ...
Page 3-314
... Storage of Aero- sol Products , 1990 edition NFPA 40 , Standard for the Storage and Handling of Cellu- lose Nitrate Motion Picture Film , 1988 edition NFPA 43A , Code for the Storage of Liquid and Solid Oxidiz- ers , 1990 edition NFPA ...
... Storage of Aero- sol Products , 1990 edition NFPA 40 , Standard for the Storage and Handling of Cellu- lose Nitrate Motion Picture Film , 1988 edition NFPA 43A , Code for the Storage of Liquid and Solid Oxidiz- ers , 1990 edition NFPA ...
Page 3-381
... Storage . 3. With rack storage , use conventional wood pallets only , no slave pallets . 4. The high pressure may be used , but the required number of design sprinklers may not be reduced from that required for the lower pressure . 5 ...
... Storage . 3. With rack storage , use conventional wood pallets only , no slave pallets . 4. The high pressure may be used , but the required number of design sprinklers may not be reduced from that required for the lower pressure . 5 ...
Contents
General Building Limitations | 3-1 |
Administrative Fire and LifeSafety and Field Inspection Provisions | 3-3 |
Chapter | 3-9 |
Copyright | |
102 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied approved assembly ASTM authority having jurisdiction beams braces branch lines brick building official ceiling cement check valve classification combustible concrete masonry construction control valve curtain deck deflectors determined devices diameter dimensions distance door drain dry pipe valve duct edge equipment exceed Exception feet fire department connection fire test fire-resistance rating flange floor flow furnace grade gypsum hangers Hazard Occupancies heat horizontal hydrostatic test installed joints joist klers knot length less limited liquid limit listed load located material maximum minimum mortar nails NFPA noncombustible Obstruction opening operation percent permitted pipe system portland cement preaction pressure protection riser roof Screw SECTION side spaced specified sprinkler system sq ft standpipe system storage structural steel structural steel columns Table temperature test sample thermocouples tion tube Type U.B.C. Standard Uniform Building Code units vertical wall thickness water supply welding width wood